You are using an unsupported browser. Please upgrade your browser to a newer version to get the best experience on Human Metabolome Database.
Record Information
Version5.0
StatusExpected but not Quantified
Creation Date2012-09-11 17:29:05 UTC
Update Date2021-09-14 15:15:56 UTC
HMDB IDHMDB0029237
Secondary Accession Numbers
  • HMDB29237
Metabolite Identification
Common NameCyanidin 3-(6''-succinyl-glucoside)
DescriptionCyanidin 3-(6''-succinyl-glucoside) belongs to the class of organic compounds known as 2-arylbenzofuran flavonoids. These are phenylpropanoids containing the 2-phenylbenzofuran moiety. Cyanidin 3-(6''-succinyl-glucoside) is found, on average, in the highest concentration within strawberries (Fragaria X ananassa). This could make cyanidin 3-(6''-succinyl-glucoside) a potential biomarker for the consumption of these foods. Based on a literature review very few articles have been published on Cyanidin 3-(6''-succinyl-glucoside).
Structure
Data?1582753391
Synonyms
ValueSource
Cyanidin 3-(6-O-succinoyl-beta-D-glucopyranoside)HMDB
Cyanidin 3-O-(6''-succinyl-glucoside)HMDB
Chemical FormulaC25H25O14
Average Molecular Weight549.4576
Monoisotopic Molecular Weight549.124430508
IUPAC Name3-{[(2S,3R,4S,5S,6R)-6-{[(3-carboxypropanoyl)oxy]methyl}-3,4,5-trihydroxyoxan-2-yl]oxy}-2-(3,4-dihydroxyphenyl)-5,7-dihydroxy-1lambda4-chromen-1-ylium
Traditional Name3-{[(2S,3R,4S,5S,6R)-6-{[(3-carboxypropanoyl)oxy]methyl}-3,4,5-trihydroxyoxan-2-yl]oxy}-2-(3,4-dihydroxyphenyl)-5,7-dihydroxy-1lambda4-chromen-1-ylium
CAS Registry Number216692-08-9
SMILES
[H][C@]1(COC(=O)CCC(O)=O)O[C@@]([H])(OC2=CC3=C(O)C=C(O)C=C3[O+]=C2C2=CC=C(O)C(O)=C2)[C@]([H])(O)[C@@]([H])(O)[C@]1([H])O
InChI Identifier
InChI=1S/C25H24O14/c26-11-6-14(28)12-8-17(24(37-16(12)7-11)10-1-2-13(27)15(29)5-10)38-25-23(35)22(34)21(33)18(39-25)9-36-20(32)4-3-19(30)31/h1-2,5-8,18,21-23,25,33-35H,3-4,9H2,(H4-,26,27,28,29,30,31)/p+1/t18-,21-,22+,23-,25-/m1/s1
InChI KeyMIYGQTFETYBMKF-WVXUANQFSA-O
Chemical Taxonomy
Description Belongs to the class of organic compounds known as 2-arylbenzofuran flavonoids. These are phenylpropanoids containing the 2-phenylbenzofuran moiety.
KingdomOrganic compounds
Super ClassPhenylpropanoids and polyketides
Class2-arylbenzofuran flavonoids
Sub ClassNot Available
Direct Parent2-arylbenzofuran flavonoids
Alternative Parents
Substituents
  • 2-arylbenzofuran flavonoid
  • Hydroxyflavonoid
  • 4'-hydroxyflavonoid
  • 5-hydroxyflavonoid
  • 7-hydroxyflavonoid
  • Dibenzopyran
  • Benzopyran
  • 2-benzopyran
  • 1-benzopyran
  • Benzofuran
  • Resorcinol
  • 1-hydroxy-4-unsubstituted benzenoid
  • 1-hydroxy-2-unsubstituted benzenoid
  • Ketal
  • Phenol
  • Monocyclic benzene moiety
  • Benzenoid
  • Furan
  • Heteroaromatic compound
  • Oxacycle
  • Acetal
  • Organoheterocyclic compound
  • Polyol
  • Organic oxygen compound
  • Hydrocarbon derivative
  • Organooxygen compound
  • Aromatic heteropolycyclic compound
Molecular FrameworkAromatic heteropolycyclic compounds
External DescriptorsNot Available
Ontology
Disposition

Route of exposure:

Source:

Biological location:

Physical Properties
StateNot Available
Experimental Molecular Properties
PropertyValueReference
Melting PointNot AvailableNot Available
Boiling PointNot AvailableNot Available
Water SolubilityNot AvailableNot Available
LogPNot AvailableNot Available
Predicted Molecular Properties
PropertyValueSource
Water Solubility0.36 g/LALOGPS
logP1.68ALOGPS
logP0.61ChemAxon
logS-3.2ALOGPS
pKa (Strongest Acidic)3.66ChemAxon
pKa (Strongest Basic)-3.6ChemAxon
Physiological Charge-1ChemAxon
Hydrogen Acceptor Count13ChemAxon
Hydrogen Donor Count8ChemAxon
Polar Surface Area236.81 ŲChemAxon
Rotatable Bond Count9ChemAxon
Refractivity136.3 m³·mol⁻¹ChemAxon
Polarizability52.05 ųChemAxon
Number of Rings4ChemAxon
BioavailabilityNoChemAxon
Rule of FiveNoChemAxon
Ghose FilterNoChemAxon
Veber's RuleNoChemAxon
MDDR-like RuleYesChemAxon
Predicted Spectral Properties

Collision Cross Sections

NameAdductTypeData SourceValueReference
DarkChem[M+H]+PredictedNot Available226.27231661259
DarkChem[M-H]-PredictedNot Available221.41431661259

Retention Indices

Underivatized

Not Available

Derivatized

DerivativeValueReference
Cyanidin 3-(6''-succinyl-glucoside),1TMS,#14897.8955Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TMS,#24929.397Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TMS,#34975.608Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TMS,#44943.4946Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TMS,#54957.1987Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TMS,#64961.4126Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TMS,#74932.2803Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TMS,#84944.0083Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#14733.82Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#24749.012Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#34716.2954Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#44725.657Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#54802.482Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#64780.8174Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#74786.1846Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#84803.7095Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#94795.8584Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#104805.6094Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#114813.9453Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#124796.505Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#134827.415Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#144824.8Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#154808.1694Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#164841.198Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#174785.5283Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#184799.512Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#194808.213Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#204787.1523Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#214820.814Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#224825.56Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#234819.876Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#244800.062Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#254834.5796Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#264875.505Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#274848.147Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TMS,#284850.289Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#14581.001Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#24531.4165Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#34537.3804Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#44653.922Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#54620.5557Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#64645.471Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#74546.2593Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#84554.5903Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#94672.3037Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#104638.1475Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#114662.7705Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#124623.854Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#134622.0615Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#144586.485Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#154614.616Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#164627.915Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#174590.5176Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#184618.138Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#194717.9824Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#204754.659Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#214728.198Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#224690.8945Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#234658.5225Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#244694.8413Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#254602.575Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#264611.5938Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#274643.1973Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#284609.517Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#294646.6606Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#304653.6196Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#314647.0854Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#324614.7793Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#334652.7866Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#344730.5996Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#354752.705Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#364720.659Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#374746.784Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#384767.962Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#394652.7886Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#404657.1Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#414734.638Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#424616.562Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#434620.553Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#444658.146Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#454666.089Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#464665.4043Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#474719.8276Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#484742.7446Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#494725.9126Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#504709.2036Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#514700.0664Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#524733.142Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#534725.763Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#544745.446Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#554716.289Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TMS,#564805.516Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#14490.6943Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#24496.933Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#34519.621Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#44478.4097Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#54517.26Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#64492.328Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#74466.7324Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#84437.1924Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#94471.9004Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#104471.2095Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#114440.09Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#124474.7134Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#134584.543Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#144606.8286Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#154589.8125Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#164524.0703Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#174496.519Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#184462.279Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#194498.219Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#204500.8306Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#214464.065Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#224499.7505Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#234614.568Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#244632.3843Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#254619.1885Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#264565.0737Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#274522.609Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#284559.7256Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#294541.1777Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#304561.7812Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#314549.169Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#324547.385Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#334563.153Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#344555.7627Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#354717.161Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#364626.3135Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#374634.797Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#384522.969Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#394526.536Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#404614.707Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#414488.613Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#424492.8193Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#434520.0703Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#444526.0874Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#454554.879Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#464559.83Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#474571.6626Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#484581.0664Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#494552.0474Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#504545.1943Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#514581.846Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#524569.47Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#534574.0576Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#544561.7417Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#554701.442Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#564725.205Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#574589.439Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#584597.2476Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#594595.2007Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#604599.14Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#614604.864Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#624579.676Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#634586.9946Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#644566.8013Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#654606.808Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#664679.093Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#674674.5693Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#684683.2866Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#694667.8545Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),4TMS,#704685.916Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TBDMS,#15216.4014Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TBDMS,#25190.748Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TBDMS,#35210.8867Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TBDMS,#45226.315Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TBDMS,#55232.3213Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TBDMS,#65218.268Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TBDMS,#75193.415Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),1TBDMS,#85201.254Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#15236.8193Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#25253.831Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#35239.621Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#45229.0283Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#55295.172Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#65268.1816Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#75279.516Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#85258.2656Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#95248.4644Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#105247.387Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#115258.3374Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#125242.588Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#135277.2935Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#145281.8213Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#155265.6396Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#165300.4624Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#175272.325Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#185270.8613Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#195273.536Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#205258.21Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#215295.6807Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#225308.6885Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#235271.8354Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#245258.534Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#255294.2534Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#265327.056Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#275306.858Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),2TBDMS,#285311.9536Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#15269.637Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#25276.4404Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#35264.8623Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#45287.857Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#55252.5205Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#65275.1Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#75307.982Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#85297.1123Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#95324.387Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#105288.8687Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#115311.7856Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#125306.559Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#135279.7783Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#145246.8467Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#155264.391Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#165269.1064Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#175237.4717Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#185252.376Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#195338.373Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#205357.6167Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#215343.902Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#225310.9697Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#235288.4995Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#245324.298Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#255337.499Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#265326.612Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#275282.1836Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#285261.383Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#295293.9746Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#305318.958Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#315278.61Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#325258.8403Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#335289.2617Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#345332.0347Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#355350.733Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#365329.0845Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#375365.1704Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#385382.8223Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#395314.301Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#405309.965Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#415361.842Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#425294.4927Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#435289.3696Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#445327.6406Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#455323.823Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#465351.0386Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#475313.747Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#485331.601Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#495337.6357Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#505309.0674Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#515321.939Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#525353.69Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#535309.989Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#545325.6636Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#555305.2344Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Cyanidin 3-(6''-succinyl-glucoside),3TBDMS,#565422.7026Lange, M. and Fedorova, M. (2020) Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST SRM 1950 metabolites in human plasma. Anal. Bioanal. Chem. 412(15), 3573-3584.
Spectra

GC-MS

Spectrum TypeDescriptionSplash KeyDeposition DateView
Predicted GC-MSPredicted GC-MS Spectrum - GC-MS (Non-derivatized) - 70eV, Positivesplash10-001r-9560540000-11205316233ccd1196ca2017-09-01View Spectrum
Predicted GC-MSPredicted GC-MS Spectrum - GC-MS (2 TMS) - 70eV, Positivesplash10-004i-9531037000-60b6eb1d35cd54bbb24e2017-10-06View Spectrum

LC-MS/MS

Spectrum TypeDescriptionSplash KeyDeposition DateView
Predicted LC-MS/MSPredicted LC-MS/MS Spectrum - 10V, Positivesplash10-0udi-0000090000-a28b6ae1c9984e1cc3952016-06-03View Spectrum
Predicted LC-MS/MSPredicted LC-MS/MS Spectrum - 20V, Positivesplash10-0udi-1000090000-2b63f5c3321dcfe2bd902016-06-03View Spectrum
Predicted LC-MS/MSPredicted LC-MS/MS Spectrum - 40V, Positivesplash10-002b-3920030000-0201f31e67904d205c232016-06-03View Spectrum
Predicted LC-MS/MSPredicted LC-MS/MS Spectrum - 10V, Negativesplash10-0002-0000090000-a3e6091c4e3b87abffea2016-08-03View Spectrum
Predicted LC-MS/MSPredicted LC-MS/MS Spectrum - 20V, Negativesplash10-0002-4200090000-2b095a6358fa5fcdc91f2016-08-03View Spectrum
Predicted LC-MS/MSPredicted LC-MS/MS Spectrum - 40V, Negativesplash10-066r-8900000000-27ed60ebea9c636697b12016-08-03View Spectrum
Biological Properties
Cellular Locations
  • Cytoplasm
  • Extracellular
Biospecimen LocationsNot Available
Tissue LocationsNot Available
Pathways
Normal Concentrations
Not Available
Abnormal Concentrations
Not Available
Associated Disorders and Diseases
Disease ReferencesNone
Associated OMIM IDsNone
DrugBank IDNot Available
Phenol Explorer Compound ID24
FooDB IDFDB000013
KNApSAcK IDNot Available
Chemspider ID30776741
KEGG Compound IDNot Available
BioCyc IDNot Available
BiGG IDNot Available
Wikipedia LinkNot Available
METLIN IDNot Available
PubChem Compound100917934
PDB IDNot Available
ChEBI IDNot Available
Food Biomarker OntologyNot Available
VMH IDNot Available
MarkerDB IDNot Available
References
Synthesis ReferenceNot Available
Material Safety Data Sheet (MSDS)Not Available
General ReferencesNot Available